{"title":"Agilent Helium Leak Detectors","description":"\u003cp\u003eWhen a leak is too small to find with soap bubbles or a pressure gauge, a helium leak detector is the tool that saves the day. Agilent helium leak detectors trace helium, a tiny, inert, harmless gas, through a mass spectrometer to pinpoint leaks that would otherwise go unnoticed until they cause a real problem. The result is testing that is fast, repeatable, and sensitive enough to catch faults long before they threaten your product or your process.\u003c\/p\u003e\n\u003cp style=\"margin-top: 12px;\"\u003eProvac stocks both new and rebuilt Agilent helium leak detectors, and we back them with in-house repair, calibration, and warranty support. Whether you need a portable unit for field service or a benchtop instrument for a production line, we can help you find the detector that matches your work and keep it accurate for years.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eHow Helium Leak Detection Works\u003c\/h3\u003e\n\u003cp\u003eThe method is clever in its simplicity. Helium is a very small molecule, so it slips through even the finest gaps. It is also rare in ordinary air and completely inert, which means it will not react with your parts and will not trigger false readings from background gases. To test a part, you introduce helium on one side of a suspected leak and let the detector sample the other side. If helium reaches the detector, the mass spectrometer identifies it instantly and reports how much is getting through.\u003c\/p\u003e\n\u003cp style=\"margin-top: 12px;\"\u003eThat readout does more than tell you whether a leak exists. It tells you how large the leak is, which lets you decide whether a part passes, needs rework, or should be rejected. For manufacturers who have to certify leak-tight assemblies, that quantitative result is the difference between guessing and knowing.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eWhere Helium Leak Detectors Are Used\u003c\/h3\u003e\n\u003cp\u003eHelium leak detection shows up anywhere a seal, weld, or joint has to hold vacuum or pressure reliably. Common uses include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommissioning and troubleshooting vacuum systems, where a single small leak can keep a chamber from reaching base pressure\u003c\/li\u003e\n\u003cli\u003eHVAC and refrigeration work, where technicians verify that sealed circuits will hold their charge\u003c\/li\u003e\n\u003cli\u003eSemiconductor and analytical instrument manufacturing, where leak-tight components are essential\u003c\/li\u003e\n\u003cli\u003eResearch and quality assurance labs that need traceable, documented leak testing\u003c\/li\u003e\n\u003cli\u003eAutomotive, aerospace, and medical device production, where safety depends on sealed assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003ePortable and Benchtop Options\u003c\/h3\u003e\n\u003cp\u003eNot every job calls for the same kind of detector. Portable units are built for mobility, so you can carry them to a large chamber, a rooftop unit, or a customer site and test wherever the work is. Benchtop detectors trade portability for maximum sensitivity and throughput, which makes them a natural fit for production lines and busy labs that test part after part all day.\u003c\/p\u003e\n\u003cp style=\"margin-top: 12px;\"\u003eBoth styles rely on internal turbo and roughing pumps to reach the low pressures the mass spectrometer needs. In many cases those are the very same Agilent \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-turbo-pumps\" title=\"Agilent Turbo Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003eturbo pumps\u003c\/a\u003e and \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-scroll-pumps\" title=\"Agilent Scroll Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003escroll pumps\u003c\/a\u003e that Provac sells as standalone units, which means the expertise and spare parts you get from us cover the detector and the pumps inside it alike.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eKeeping Your Detector Accurate\u003c\/h3\u003e\n\u003cp\u003eA leak detector is only as trustworthy as its last calibration. Sensitivity drifts over time, pumps wear, and spectrometer cells eventually need attention. Provac keeps your instrument dependable with a full range of service, so you never have to wonder whether a passing result is real.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration and sensitivity verification against known standards\u003c\/li\u003e\n\u003cli\u003eRepair of internal pumps, valves, and spectrometer cells\u003c\/li\u003e\n\u003cli\u003eRebuilt detectors that are tested and warranty backed before they ship\u003c\/li\u003e\n\u003cli\u003eGuidance on test methods, from spray probe tracing to hard vacuum testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eUnderstanding Leak Rate and Sensitivity\u003c\/h3\u003e\n\u003cp\u003eOne term you will hear again and again in leak testing is leak rate, usually expressed in units that describe how much gas passes through a leak over time. A detector's sensitivity is its ability to register very small leak rates, and the best helium leak detectors can sense leaks far below what any other practical method could find. This matters because not every application needs the same sensitivity. A refrigeration technician confirming that a circuit will hold its charge has different needs from a semiconductor manufacturer certifying an ultra-high vacuum flange. When you talk with Provac about a detector, we help you match its sensitivity to the leak rates your work actually demands, so you are neither underequipped nor paying for more instrument than you need.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eTest Methods You Can Use\u003c\/h3\u003e\n\u003cp\u003eHelium leak detectors support more than one way of finding a leak, and knowing your options helps you choose the right instrument. In the spray, or outside-in, method, you pump the part down with the detector and spray helium around the outside, watching for the moment helium finds its way in. In the accumulation or sniffer method, you pressurize the part with helium and move a probe around the outside to find where it escapes. Hard vacuum testing offers the highest sensitivity for critical parts. Different detectors are optimized for different methods, so it helps to know how you plan to test before you buy.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eBuying New Versus Rebuilt\u003c\/h3\u003e\n\u003cp\u003eA rebuilt helium leak detector can be a smart way to get professional-grade leak testing without the price of a brand new instrument. When Provac rebuilds a detector, we service the internal pumps, check and restore the spectrometer, verify sensitivity against known standards, and back the finished unit with a warranty. For many shops and labs, a rebuilt detector performs every bit as well as new for the work they do, and the savings can be put toward calibration, training, or spare parts. If your application demands the very latest features or the highest possible sensitivity, a new unit may be the better path. Either way, we will lay out the honest tradeoffs so you can decide based on your actual needs rather than a sales pitch, and we will support the instrument for the long haul.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eSupport That Comes With Your Detector\u003c\/h3\u003e\n\u003cp\u003eA leak detector is an instrument you will rely on for years, so the support behind it matters as much as the hardware itself. Provac stands behind every detector we sell with parts, service, and straightforward advice when a question comes up. Because we also stock and service the pumps, gauges, and fittings that surround a detector, you are not left stitching together help from several vendors when something needs attention. That single point of contact saves time and keeps your testing running.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eWhy Choose Provac for Leak Detection\u003c\/h3\u003e\n\u003cp\u003eBuying a leak detector is not just a hardware decision. It is a decision about the support you will have when the instrument needs care, and about whether the person selling it understands how leak testing actually works. Provac has spent decades in vacuum technology, and that background means we can talk through your application, recommend a detector that fits, and stand behind it long after the sale.\u003c\/p\u003e\n\u003cp style=\"margin-top: 12px;\"\u003eBecause we also stock the pumps, gauges, and fittings that surround a detector, we can help with the whole test setup rather than just the box on the cart. See the full \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent\" title=\"Agilent\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003eAgilent\u003c\/a\u003e collection to explore how helium leak detectors work alongside Agilent \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-turbo-pumps\" title=\"Agilent Turbo Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003eturbo pumps\u003c\/a\u003e, \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-scroll-pumps\" title=\"Agilent Scroll Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003escroll pumps\u003c\/a\u003e, \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-pumping-stations\" title=\"Agilent Pumping Stations\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003epumping stations\u003c\/a\u003e, \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-diffusion-pumps\" title=\"Agilent Diffusion Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003ediffusion pumps\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.provac.com\/collections\/agilent-ion-pumps\" title=\"Agilent Ion Pumps\" style=\"font-family: 'Open Sans', sans-serif; font-size: 14px; letter-spacing: .5px; font-weight: 400; color: #23527c;\"\u003eion pumps\u003c\/a\u003e. When you are ready to choose, call 831-462-8900 and we will help you match a detector to your test method and your budget.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 24px;\"\u003eAgilent Helium Leak Detectors FAQ\u003c\/h3\u003e\n\u003ch4 style=\"margin-top: 16px;\"\u003e1. Do you offer both portable and benchtop detectors?\u003c\/h4\u003e\n\u003cp\u003eYes. Portable units suit field service and large chambers, while benchtop units offer maximum sensitivity for production and lab use.\u003c\/p\u003e\n\u003ch4 style=\"margin-top: 16px;\"\u003e2. Can you calibrate and repair my existing detector?\u003c\/h4\u003e\n\u003cp\u003eWe can. Provac offers calibration, sensitivity verification, and repair of the internal pumps, valves, and spectrometer cells.\u003c\/p\u003e\n\u003ch4 style=\"margin-top: 16px;\"\u003e3. Why helium instead of another tracer gas?\u003c\/h4\u003e\n\u003cp\u003eHelium is small enough to find tiny leaks, rare enough in air to avoid false readings, and completely inert, so it will not react with your parts.\u003c\/p\u003e\n\u003ch4 style=\"margin-top: 16px;\"\u003e4. What test methods do these detectors support?\u003c\/h4\u003e\n\u003cp\u003eDetectors support the spray, or outside-in, method where helium is sprayed around a part under vacuum, the accumulation or sniffer method where a pressurized part is probed for escaping helium, and hard vacuum testing for the highest sensitivity on critical parts. Different detectors are optimized for different methods, so it helps to know your test method before you buy.\u003c\/p\u003e\n\u003ch4 style=\"margin-top: 16px;\"\u003e5. Should I buy a new or rebuilt detector?\u003c\/h4\u003e\n\u003cp\u003eA rebuilt detector has its internal pumps serviced, its spectrometer checked and restored, and its sensitivity verified against known standards before shipping with a warranty, and it performs every bit as well as new for most shops and labs. A new unit may be the better path if your application demands the very latest features or the highest possible sensitivity.\u003c\/p\u003e","products":[{"product_id":"varian-979-helium-leak-detector-rebuilt","title":"Varian 979 Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $13,194.00\u003cbr\u003e\u003cstrong\u003eMin. detectable sensitivity\u003c\/strong\u003e: 5 x 10-10 atm cc\/sec (standard sensitivity)\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/979.pdf?v=1679586337\" target=\"_blank\" title=\"Varian 979 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_979_Operational_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 979 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"979","offer_id":846302839,"sku":null,"price":13194.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_979_1.jpg?v=1560976735"},{"product_id":"varian-979d-helium-leak-detector-rebuilt","title":"Varian 979D Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $16,980.00\u003cbr\u003e\u003cstrong\u003eMin. detectable sensitivity\u003c\/strong\u003e: 5 x 10-10 atm cc\/sec (standard sensitivity)\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/979.pdf?v=1679586337\" target=\"_blank\" title=\"Varian 979D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_979_Operational_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 979D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"979D","offer_id":846302847,"sku":null,"price":16980.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_979_1_35207e71-7126-454d-b529-f483bc9c3dcf.jpg?v=1560976893"},{"product_id":"varian-959-50-helium-leak-detector-rebuilt","title":"Varian 959-50 Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $11,572.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 50 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003eTechnical Sheet\u003cbr\u003eManual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302851,"sku":null,"price":11572.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_959-50_2.jpg?v=1560976547"},{"product_id":"varian-959d-helium-leak-detector-rebuilt","title":"Varian 959D Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $15,357.00\u003cbr\u003e\u003cstrong\u003eInput flange\u003c\/strong\u003e: KF25\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 50 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/959_959D.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 959D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_959_Operational_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 959D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302863,"sku":null,"price":15357.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_959D_2.jpg?v=1560976541"},{"product_id":"varian-938-41-diffusion-pump-helium-leak-detector-rebuilt","title":"Varian 938-41 Helium Leak Detector with Diffusion Pump, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $8,868.00\u003cbr\u003e\u003cstrong\u003eMotor\u003c\/strong\u003e: 1 Phase, 115\/208-220V, 50\/60Hz\u003cbr\u003e\u003cstrong\u003eMin. detectable sensitivity\u003c\/strong\u003e: 2 x 10-10 atm cc\/sec (He) | 8 x 10-11 atm cc\/sec (air)\u003cbr\u003e\u003cstrong\u003ePower requirements\u003c\/strong\u003e: 1 Phase, 115V (230V), 50\/60Hz\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 142 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/938-41.pdf?v=1679586337\" target=\"_blank\" title=\"Varian 938-41 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_938-41_HLD_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 938-41 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302867,"sku":null,"price":8868.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_938-41_w_diffusion_edit_2.jpg?v=1566245815"},{"product_id":"varian-938-41-turbo-pump-helium-leak-detector-rebuilt","title":"Varian 938-41 Helium Leak Detector with Turbo Pump, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $10,491.00\u003cbr\u003e\u003cstrong\u003eMinimal detectable sensitivity\u003c\/strong\u003e: 2 x 10-10 atm cc\/sec (He) | 8 x 10-11 atm cc\/sec (air)\u003cbr\u003e\u003cstrong\u003ePower requirements\u003c\/strong\u003e: 1 Phase, 115V (230V), 50\/60Hz\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 142 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/938-41.pdf?v=1679586337\" target=\"_blank\" title=\"Varian 938-41 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_938-41_HLD_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 938-41 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302875,"sku":null,"price":10491.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_938-41_w_turbo_1.jpg?v=1560974609"},{"product_id":"varian-947-helium-leak-detector-rebuilt","title":"Varian 947 Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $11,627.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 510 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/947_948_960.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 947 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_947_948_960_Op_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 947 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302883,"sku":null,"price":11627.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_947_1.jpg?v=1560975060"},{"product_id":"varian-947d-helium-leak-detector-rebuilt","title":"Varian 947D Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $16,223.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 510 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/947_948_960.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 947D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_947_948_960_Op_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 947D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302891,"sku":null,"price":16223.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_947_1_f1508f6a-6492-4c56-af3f-ca70932ed546.jpg?v=1560975101"},{"product_id":"varian-948-helium-leak-detector-rebuilt","title":"Varian 948 Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $10,274.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 510 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/947_948_960.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 948 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_947_948_960_Op_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 948 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302899,"sku":null,"price":10274.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_947_1_27ac0dee-19c4-4a22-b71e-4c4d3b95368b.jpg?v=1560975120"},{"product_id":"varian-948d-helium-leak-detector-rebuilt","title":"Varian 948D Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $16,223.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 510 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/947_948_960.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 948D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_947_948_960_Op_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 948D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846302903,"sku":null,"price":16223.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_947_1_0734ff3b-3fef-427f-9ddf-f7f536f54c61.jpg?v=1560975141"},{"product_id":"varian-956-diffusion-pump-and-oil-sealed-vane-helium-leak-detector","title":"Varian 956 Helium Leak Detector with Diffusion Pump \u0026 Oil Sealed Vane, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $8,166.00\u003cbr\u003e\u003cstrong\u003eHelium sensitivity\u003c\/strong\u003e: 2 x 10-10 atm cc\/sec\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/956_956D.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 956 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_956_Instruction_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 956 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"956 With A Diffusion Pump And Oil Sealed Vane","offer_id":846302919,"sku":null,"price":8166.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_956_1.jpg?v=1560975538"},{"product_id":"varian-956-turbo-pump-and-oil-sealed-vane-helium-leak-detector","title":"Varian 956 Helium Leak Detector with Turbo Pump \u0026 Oil Sealed Vane, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $9,788.00\u003cbr\u003e\u003cstrong\u003eHelium sensitivity\u003c\/strong\u003e: 2 x 10-10 atm cc\/sec\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/956_956D.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 956 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_956_Instruction_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 956 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"956 With A Turbo Pump And Oil Sealed Vane","offer_id":846302927,"sku":null,"price":9788.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_956_1_7ff1f2d7-7322-459d-8098-9d2d389d5363.jpg?v=1560975583"},{"product_id":"varian-956d-turbo-pump-and-dry-scroll-helium-leak-detector","title":"Varian 956D Helium Leak Detector with Turbo Pump \u0026 Dry Scroll, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $13,033.00\u003cbr\u003e\u003cstrong\u003eHelium sensitivity\u003c\/strong\u003e: 2 x 10-10 atm cc\/sec\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/956_956D.pdf?v=1679586339\" target=\"_blank\" title=\"Varian 956D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Varian_956_Instruction_Manual.pdf?v=1679586189\" target=\"_blank\" title=\"Varian 956D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"956D With A Turbo Pump And Dry Scroll","offer_id":846302939,"sku":null,"price":13033.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_956_1_c878ea71-a260-47b6-8224-03c8d5ab4fb3.jpg?v=1560975617"},{"product_id":"varian-agilent-949-helium-leak-detector","title":"Varian 949 Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Varian\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003eTechnical Sheet\u003cbr\u003eManual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":14211449542,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Varian_947_1_6189994d-dd89-4167-bc55-c82112b0c9ab.jpg?v=1560975229"},{"product_id":"agilent-hld-mr15-mobile-leak-detector","title":"Agilent HLD MR15 Mobile Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 179 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_MR15_MR30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD MR15 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD MR15 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":16830018694,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_MD30_Mobile_1_bdcd3db6-bd04-43c6-8da1-aa498d2229e9.jpg?v=1557944046"},{"product_id":"agilent-hld-md30-helium-leak-detector","title":"Agilent HLD MD30 Mobile Dry Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_MD15_MD30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD MD30 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD MD30 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":16830132678,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_MD30_1.jpg?v=1557943744"},{"product_id":"agilent-hld-br15-helium-leak-detector","title":"Agilent HLD BR15 Bench Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 179 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_BR15_BR30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD BR15 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD BR15 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":16830218502,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Untitled-1_479c73d9-8cc0-4c54-b5c3-52d93da419f1.jpg?v=1555018897"},{"product_id":"agilent-hld-bd30-bench-mount-leak-detector","title":"Agilent HLD BD30 Bench Dry Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\u003cbr\u003eVideos Coming Soon.\u003cbr\u003eComing Soon.\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_BD15_BD30.pdf?2064\" target=\"_blank\" title=\"Agilent HLD BD30 Bench Dry Helium Leak Detector Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Agilent_VS_Series_HLD_Manual.pdf?11990537588715519745\" target=\"_blank\" title=\"Agilent HLD BD30 Bench Dry Helium Leak Detector Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":16830309254,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Untitled-1.jpg?v=1555018162"},{"product_id":"agilent-vs-c15-component-leak-detector","title":"Agilent VS C15 Component Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003eMinimal detectable leak\u003c\/strong\u003e: 5 x 10-10 mbar l\/s\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/VS_C15.pdf?v=1614325526\" target=\"_blank\" title=\"Agilent VS C15 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/VS_C15_manual.pdf?v=1614325525\" target=\"_blank\" title=\"Agilent VS C15 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303030054996,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_VS_C15_1.jpg?v=1558568359"},{"product_id":"agilent-hld-pd03-portable-dry-leak-detector","title":"Agilent HLD PD03 Portable Dry Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_PD03_PR02.pdf?v=1614320299\" target=\"_blank\" title=\"Agilent HLD PD03 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD PD03 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303042539604,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_BD15_1_bb527150-55aa-477c-ae18-fb8c31f9c21f.jpg?v=1557944600"},{"product_id":"agilent-hld-mr30-mobile-leak-detector","title":"Agilent HLD MR30 Mobile Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent \u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_MR15_MR30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD MR30 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD MR30 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303122395220,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_MD30_Mobile_1_4311d794-a736-4d85-a1fd-4e929b568b3a.jpg?v=1557944108"},{"product_id":"agilent-hld-bd15-bench-dry-leak-detector","title":"Agilent HLD BD15 Bench Dry Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent \u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_BD15_BD30.pdf?2064\" target=\"_blank\" title=\"Agilent HLD BD15 Bench Dry Helium Leak Detector Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1600279632\" target=\"_blank\" title=\"Agilent HLD BD15 Bench Dry Helium Leak Detector Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303128326228,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_BD15_1.jpg?v=1557943331"},{"product_id":"agilent-hld-br30-bench-leak-detector","title":"Agilent HLD BR30 Bench Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_BR15_BR30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD BR30 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD BR30 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303167516756,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_BD15_1_7d8fd780-4fef-46d3-b574-c986678e6fc9.jpg?v=1557943440"},{"product_id":"agilent-hld-md15-mobile-leak-detector","title":"Agilent HLD MD15 Mobile Dry Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent \u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_MD15_MD30.pdf?v=1614320300\" target=\"_blank\" title=\"Agilent HLD MD15 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD MD15 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303170007124,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_MD30_Mobile_1.jpg?v=1557943899"},{"product_id":"agilent-hld-pr02-portable-leak-detector","title":"Agilent HLD PR02 Portable Helium Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_PD03_PR02.pdf?v=1614320299\" target=\"_blank\" title=\"Agilent HLD PR02 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD PR02 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303207100500,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_BD15_1_184a47fc-7441-46f1-8ca7-f8575e00086c.jpg?v=1557944626"},{"product_id":"agilent-phd-4-leak-detector-sniffer","title":"Agilent PHD-4 Sniffer","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cb\u003ePower\u003c\/b\u003e: 100-240V, 50\/60Hz\u003cbr\u003e\u003cb\u003eMinimal detectable leak\u003c\/b\u003e: 5 x 10-6 mbar (He)\u003cbr\u003e\u003cstrong\u003eMinimum detectable concentration\u003c\/strong\u003e: from 2 ppm (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 6 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/PHD-4.pdf?v=1614320304\" target=\"_blank\" title=\"Agilent PHD-4 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/PHD-4_Sniffer_Manual.pdf?v=1614285809\" target=\"_blank\" title=\"Agilent PHD-4 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21303213031508,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/AgilentPHD-4_1.jpg?v=1629221330"},{"product_id":"agilent-hld-pd03-portable-dry-helium-leak-detector-factory-rebuilt","title":"Agilent HLD PD03 Portable Dry Helium Leak Detector, Factory Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: factory rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_PD03_PR02.pdf?v=1614320299\" target=\"_blank\" title=\"Agilent HLD PD03 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" target=\"_blank\" title=\"Agilent HLD PD03 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":32389242355796,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/AgilentHLDBD15_1.jpg?v=1591117155"},{"product_id":"agilent-multi-gas-crosslab-sniffer-leak-detector","title":"Agilent Multi-Gas CrossLab Sniffer Leak Detector","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003ePart Number: \u003c\/strong\u003e\u003ca class=\"btn btn-link plusIcon browsePartPlus\"\u003eG8613A\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 5E-5 std cc\/sec (5.1E-5 mbar • L\/sec) Helium\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: \u0026lt;1 lb.\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/data-sheet-multigas-crosslab-sniffer-leak-detector-5994-6945en-agilent.pdf?v=1741382583\" target=\"_blank\" title=\"Agilent Multi-Gas CrossLab Sniffer Leak Detector Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/data-sheet-multigas-crosslab-sniffer-leak-detector-5994-6945en-agilent.pdf?v=1741382583\" target=\"_blank\" title=\"Agilent Multi-Gas CrossLab Sniffer Leak Detector Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":41903071854676,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/slot1-how-it-works-electronic-leak-detector.webp?v=1740784717"},{"product_id":"agilent-hld-md30-mobile-dry-helium-leak-detector-rebuilt","title":"Agilent HLD MD30 Mobile Dry Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Agilent\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $33,000.00\u003cbr\u003e\u003cstrong\u003ePumping speed\u003c\/strong\u003e: 1.8 l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 203 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/HLD_MD15_MD30.pdf?v=1614320300\" title=\"Agilent HLD MD30 Technical Data Sheet\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/BD15_BD30_BR15_MD15_MD30_MR15_PD03.pdf?v=1614332636\" title=\"Agilent HLD MD30 Instruction Manual\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":47395844325460,"sku":null,"price":33000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Agilent_HLD_MD30_1.jpg?v=1557943744"}],"url":"https:\/\/www.provac.com\/collections\/agilent-helium-leak-detectors.oembed?page=2","provider":"Provac","version":"1.0","type":"link"}