{"title":"Edwards Helium Leak Detectors","description":"\u003cp\u003eA leak can turn a well-designed vacuum system into a slow, unreliable one. Edwards helium leak detectors find and measure leaks quickly, so you can fix the problem rather than guess at it. At Provac Sales, we supply Edwards Spectron and ELD500 helium leak detectors and provide repair service for supported Edwards Spectron units.\u003c\/p\u003e\n\u003cp\u003eHelium mass spectrometer leak detection is the standard method for vacuum systems and sealed components because helium is light, inert, safe and present in only tiny amounts in normal air. That makes even a small helium signal a clear sign of a leak.\u003c\/p\u003e\n\n\u003ch2\u003eEdwards Leak Detector Models We Carry\u003c\/h2\u003e\n\u003cp\u003eOur Edwards helium leak detector listings include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eEdwards Spectron 600, a long-established helium mass spectrometer leak detector used in industrial and research labs\u003c\/li\u003e\n    \u003cli\u003eEdwards Spectron 600D, a dry-backed version of the Spectron 600\u003c\/li\u003e\n    \u003cli\u003eEdwards ELD500 Wet, with an oil-sealed backing pump\u003c\/li\u003e\n    \u003cli\u003eEdwards ELD500 Dry, with an oil-free backing pump\u003c\/li\u003e\n    \u003cli\u003eEdwards ELD500 Flex, a configurable version for different testing needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe wet, dry and flex designations refer mainly to the backing pump and configuration inside the detector. Dry versions avoid oil in the instrument and are preferred for clean applications, while wet versions can offer a lower purchase cost. Each listing shows the voltage and configuration of that unit.\u003c\/p\u003e\n\n\u003ch2\u003eHow Helium Leak Detection Works\u003c\/h2\u003e\n\u003cp\u003eA helium leak detector contains a small mass spectrometer tuned to detect helium ions. The test object is connected to the detector, or the detector is connected to a vacuum system. Helium is then sprayed around suspected leak points, or the part is filled with helium and the detector samples the surrounding area.\u003c\/p\u003e\n\u003cp\u003eWhen helium enters through a leak, the spectrometer measures it and displays a leak rate, usually in mbar l\/s or atm cc\/s. The detector's own vacuum system, including a turbo pump and backing pump, keeps the spectrometer at the low pressure it needs to work.\u003c\/p\u003e\n\n\u003ch2\u003eTest Methods Supported\u003c\/h2\u003e\n\u003cp\u003eEdwards leak detectors are typically used in three ways:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eVacuum mode, also called spray testing, where the part or system is evacuated and helium is sprayed on the outside\u003c\/li\u003e\n    \u003cli\u003eSniffer mode, where the part is pressurized with helium and a sniffer probe is moved over the outside\u003c\/li\u003e\n    \u003cli\u003eBombing or accumulation tests for sealed parts, where helium is forced in and later detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVacuum mode gives the highest sensitivity. Sniffer mode is useful for large parts, pressurized systems and production lines.\u003c\/p\u003e\n\n\u003ch2\u003eHow to Choose an Edwards Leak Detector\u003c\/h2\u003e\n\u003cp\u003eWhen selecting a model, consider:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eThe smallest leak rate you need to find\u003c\/li\u003e\n    \u003cli\u003eTest methods required, such as vacuum spray, sniffing or both\u003c\/li\u003e\n    \u003cli\u003eWhether oil-free operation is important, which points to dry versions\u003c\/li\u003e\n    \u003cli\u003eTest port size and the volume of parts or systems being tested\u003c\/li\u003e\n    \u003cli\u003ePortability, for field service versus a fixed test station\u003c\/li\u003e\n    \u003cli\u003eRequired throughput in a production environment\u003c\/li\u003e\n    \u003cli\u003eElectrical supply and available space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your work involves large chambers, an auxiliary roughing pump may be needed to reduce test time. Send us your test requirements and we will recommend a suitable configuration.\u003c\/p\u003e\n\n\u003ch2\u003eApplications for Edwards Helium Leak Detectors\u003c\/h2\u003e\n\u003cp\u003eEdwards Spectron and ELD500 detectors are used in:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eVacuum system maintenance and commissioning\u003c\/li\u003e\n    \u003cli\u003eSemiconductor tool service and qualification\u003c\/li\u003e\n    \u003cli\u003eRefrigeration, HVAC and heat exchanger testing\u003c\/li\u003e\n    \u003cli\u003eAutomotive, aerospace and battery component testing\u003c\/li\u003e\n    \u003cli\u003eMedical device and packaging seal testing\u003c\/li\u003e\n    \u003cli\u003eResearch labs, accelerators and space simulation chambers\u003c\/li\u003e\n    \u003cli\u003eProduction leak testing of welded and brazed parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eNew vs Rebuilt Leak Detectors\u003c\/h2\u003e\n\u003cp\u003eNew Edwards leak detectors suit teams that want current-production instruments and full manufacturer features. Rebuilt and serviced units can be an economical option for maintenance departments and labs that need dependable leak testing without a new-instrument budget. Always review the listing and quotation for condition, calibration status and warranty.\u003c\/p\u003e\n\n\u003ch2\u003eCalibration and Maintenance\u003c\/h2\u003e\n\u003cp\u003eAccurate leak rates depend on regular calibration with a known reference leak. Most detectors include an internal or external calibrated leak used for routine checks. Other maintenance points include:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eServicing the internal turbo pump and backing pump on schedule\u003c\/li\u003e\n    \u003cli\u003eReplacing filament or ion source components as needed\u003c\/li\u003e\n    \u003cli\u003eKeeping test ports and seals clean\u003c\/li\u003e\n    \u003cli\u003eChecking the backing pump oil on wet versions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your detector shows unstable background, slow response or calibration failures, it may need service rather than adjustment.\u003c\/p\u003e\n\n\u003ch2\u003eEdwards Spectron Repair Service\u003c\/h2\u003e\n\u003cp\u003eProvac Sales repairs supported Edwards Spectron helium leak detectors. Common issues include spectrometer tube faults, filament failure, internal pump wear and electronics problems. We also service the Edwards turbo pumps and rotary vane pumps used inside many leak detectors.\u003c\/p\u003e\n\u003cp\u003eBefore shipping a detector, submit an RMA request, complete the contamination data sheet, and pack the unit securely. See our \u003ca href=\"https:\/\/www.provac.com\/pages\/pump-repair\" style=\"color: blue; font-family: 'Open Sans', sans-serif;\"\u003epump repair page\u003c\/a\u003e for more.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is the difference between ELD500 Wet and ELD500 Dry?\u003c\/h3\u003e\n\u003cp\u003eThe wet version uses an oil-sealed backing pump and the dry version uses an oil-free backing pump. Choose dry for clean applications or where oil handling is a concern.\u003c\/p\u003e\n\n\u003ch3\u003eCan I use a Spectron 600 for sniffer testing?\u003c\/h3\u003e\n\u003cp\u003eYes, with a sniffer probe and the right setup. Sniffer sensitivity is lower than vacuum mode, so check that it meets your requirements.\u003c\/p\u003e\n\n\u003ch3\u003eHow often should a helium leak detector be calibrated?\u003c\/h3\u003e\n\u003cp\u003eMany users run a quick calibration check daily or at the start of each test session, with full service and certification on an annual basis.\u003c\/p\u003e\n\n\u003ch3\u003eWhy does my leak detector show a high helium background?\u003c\/h3\u003e\n\u003cp\u003eHelium can build up in the room, in the detector's pumps or in the test part after heavy spraying. Ventilating the area and purging the detector often helps. Persistent high background may indicate a service need.\u003c\/p\u003e\n\n\u003ch3\u003eCan I use the Spectron with large vacuum chambers?\u003c\/h3\u003e\n\u003cp\u003eYes, but large volumes slow response time. Many users add an auxiliary pump or use partial-flow mode, where the system's own pumps handle most of the gas and the detector samples a portion of it.\u003c\/p\u003e\n\n\u003ch2\u003eTips for Faster, More Reliable Leak Testing\u003c\/h2\u003e\n\u003cp\u003eGood technique often matters as much as the instrument. A few habits help Edwards leak detector users find leaks faster:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003eStart spraying helium at the top of the part and work downward, because helium is lighter than air and rises\u003c\/li\u003e\n    \u003cli\u003eUse a fine spray nozzle and low flow so you can pinpoint the leak location rather than flooding the area\u003c\/li\u003e\n    \u003cli\u003eWait for the signal to settle before moving on, especially on larger systems with slower response\u003c\/li\u003e\n    \u003cli\u003eKeep the test area ventilated to avoid helium background building up in the room\u003c\/li\u003e\n    \u003cli\u003eCheck the detector's calibration before an important test, not after a confusing result\u003c\/li\u003e\n    \u003cli\u003eRecord leak rates and locations so repeat problems are easy to track\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor production testing, fixtures and repeatable test sequences make results more consistent between operators. Our team can help you set up a test method that fits your parts and acceptance criteria, whether you are running occasional maintenance checks or a dedicated test station.\u003c\/p\u003e\n\n\u003ch2\u003eRequest a Quote on Edwards Leak Detectors\u003c\/h2\u003e\n\u003cp\u003eSend us the model you need, the configuration (wet, dry or flex), voltage and your test application. We will confirm availability or quote a Spectron repair. \u003ca href=\"https:\/\/www.provac.com\/pages\/contact-us\" style=\"color: blue; font-family: 'Open Sans', sans-serif;\"\u003eContact us\u003c\/a\u003e or call \u003cstrong\u003e831-462-8900\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between ELD500 Wet and ELD500 Dry?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The wet version uses an oil-sealed backing pump and the dry version uses an oil-free backing pump. Choose dry for clean applications or where oil handling is a concern.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use a Spectron 600 for sniffer testing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, with a sniffer probe and the right setup. Sniffer sensitivity is lower than vacuum mode, so check that it meets your requirements.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How often should a helium leak detector be calibrated?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Many users run a quick calibration check daily or at the start of each test session, with full service and certification on an annual basis.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why does my leak detector show a high helium background?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Helium can build up in the room, in the detector's pumps or in the test part after heavy spraying. Ventilating the area and purging the detector often helps. Persistent high background may indicate a service need.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use the Spectron with large vacuum chambers?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, but large volumes slow response time. Many users add an auxiliary pump or use partial-flow mode, where the system's own pumps handle most of the gas and the detector samples a portion of it.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","products":[{"product_id":"edwards-spectron-600d-helium-leak-detector","title":"Edwards Spectron 600D Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Edwards\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $12,113.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 96 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Spectron_600.pdf?v=1679586390\" target=\"_blank\" title=\"Edwards Spectron 600D Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Edwards_Spectron_600T_D_DS_Manual.pdf?v=1679586184\" target=\"_blank\" title=\"Edwards Spectron 600D Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":846306975,"sku":null,"price":12113.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Edwards_Spectron_600_1.jpg?v=1560283874"},{"product_id":"edwards-eld-500-wet-helium-leak-detector","title":"Edwards ELD500 Wet Helium Leak Detector","description":"\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Edwards\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003eInlet\u003c\/strong\u003e: KF25\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤ 5 x 10-12 mbar l\/s (vacuum op.)\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤7 x 10-9 mbar l\/s (sniffer op.)\u003cbr\u003e\u003cstrong\u003eMax. measurable leak rate\u003c\/strong\u003e: \u0026gt; 0.1 mbar l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 88 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500.pdf?v=1679586368\" target=\"_blank\" title=\"Edwards ELD500 Wet Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500_manual.pdf?v=1679586425\" target=\"_blank\" title=\"Edwards ELD500 Wet Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21361872666708,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Edwards_ELD-500_wet_1.jpg?v=1558114156"},{"product_id":"edwards-eld-500-dry-helium-leak-detector","title":"Edwards ELD500 Dry Helium Leak Detector","description":"\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Edwards\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003eInlet\u003c\/strong\u003e: KF25\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤ 3 x 10-11 mbar l\/s (vacuum op.)\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤7 x 10-9 mbar l\/s (sniffer op.)\u003cbr\u003e\u003cstrong\u003eMax. measurable leak rate\u003c\/strong\u003e: \u0026gt; 0.1 mbar l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 78 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500.pdf?v=1679586368\" target=\"_blank\" title=\"Edwards ELD500 Dry Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500_manual.pdf?v=1679586425\" target=\"_blank\" title=\"Edwards ELD500 Dry Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":21361875386452,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/Edwards_ELD-500_dry_1.jpg?v=1558114275"},{"product_id":"edwards-eld500-flex-helium-leak-detector","title":"Edwards ELD500 Flex Helium Leak Detector","description":"\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Edwards\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: new\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: ASK\u003cbr\u003e\u003cstrong\u003eInlet\u003c\/strong\u003e: KF25\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤ 5 x 10-11 mbar l\/s (vacuum op.)\u003cbr\u003e\u003cstrong\u003eLowest detectable leak rate\u003c\/strong\u003e: ≤7 x 10-9 mbar l\/s (sniffer op.)\u003cbr\u003e\u003cstrong\u003eMax. measurable leak rate\u003c\/strong\u003e: \u0026gt; 0.1 mbar l\/s (He)\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 66 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500.pdf?v=1679586368\" target=\"_blank\" title=\"Edwards ELD500 Flex Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/ELD500_manual.pdf?v=1679586425\" target=\"_blank\" title=\"Edwards ELD500 Flex Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":32228789321812,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/EdwardsELD500_flex_1.jpg?v=1588635098"},{"product_id":"edwards-spectron-600-helium-leak-detector-rebuilt","title":"Edwards Spectron 600 Helium Leak Detector, Rebuilt","description":"\u003cdiv\u003e\n\u003cdiv id=\"tabs\"\u003e\n\u003cdiv class=\"tab active-tab\"\u003e\u003ca\u003eOverview\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eSpecifications\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003eVideos\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\u003ca\u003ePump Repair\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-contents\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: helium leak detector\u003cbr\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Edwards\u003cbr\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: rebuilt\u003cbr\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e: $12,113.00\u003cbr\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 96 lbs\u003cbr\u003e*Other Configurations Available Upon Request\u003cbr\u003e\u003cstrong\u003eOUT OF STOCK ITEMS STILL AVAILABLE FOR PURCHASE, please contact\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Spectron_600.pdf?v=1679586390\" target=\"_blank\" title=\"Edwards Spectron 600 Technical Data Sheet\" rel=\"noopener noreferrer\"\u003eTechnical Sheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/files\/Edwards_Spectron_600T_D_DS_Manual.pdf?v=1679586184\" target=\"_blank\" title=\"Edwards Spectron 600 Instruction Manual\" rel=\"noopener noreferrer\"\u003eManual\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Vacuum Pumps - Provac Sales Inc.","offers":[{"title":"Default Title","offer_id":32582878625876,"sku":null,"price":12113.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/4021\/products\/EdwardsSpectron600_1.jpg?v=1596482609"}],"url":"https:\/\/www.provac.com\/collections\/edwards-helium-leak-detectors.oembed","provider":"Provac","version":"1.0","type":"link"}